TSIEN=0, ERIE=0, ESOR=0, TSIIE=0, NSCN=00000, OVRF=0, PS=000, LPSCNITV=0000, LPCLKS=0, STPE=0, STM=0, EXTERF=0
General Control and Status register
STPE | TSI STOP Enable while in low-power modes (STOP, VLPS, LLS, and VLLS{3,2,1}). 0 (0): Disable TSI when MCU goes into low-power modes. 1 (1): Allows TSI to continue running in all low-power modes. |
STM | Scan Trigger Mode 0 (0): Software trigger scan. 1 (1): Periodical Scan. |
ESOR | End-of-Scan Or Out-of-Range Interrupt Select 0 (0): Out-of-Range interrupt is allowed. 1 (1): End-of-Scan interrupt is allowed. |
ERIE | Error Interrupt Enable 0 (0): Interrupt disabled for error. 1 (1): Interrupt enabled for error. |
TSIIE | Touch Sensing Input Interrupt Module Enable 0 (0): Interrupt from TSI is disabled. 1 (1): Interrupt from TSI is enabled. |
TSIEN | Touch Sensing Input Module Enable 0 (0): TSI module is disabled. 1 (1): TSI module is enabled. |
SWTS | Software Trigger Start |
SCNIP | Scan In Progress Status |
OVRF | Overrun Error Flag 0 (0): No overrun. 1 (1): Overrun occurred. |
EXTERF | External Electrode Error Occurred 0 (0): No fault happend on TSI electrodes. 1 (1): Short to VDD or VSS was detected on one or more electrodes. |
OUTRGF | Out of Range Flag |
EOSF | End of Scan Flag |
PS | Electrode Oscillator Prescaler 0 (000): Electrode Oscillator Frequency divided by 1 1 (001): Electrode Oscillator Frequency divided by 2 2 (010): Electrode Oscillator Frequency divided by 4 3 (011): Electrode Oscillator Frequency divided by 8 4 (100): Electrode Oscillator Frequency divided by 16 5 (101): Electrode Oscillator Frequency divided by 32 6 (110): Electrode Oscillator Frequency divided by 64 7 (111): Electrode Oscillator Frequency divided by 128 |
NSCN | Number of Consecutive Scans Per Electrode Electrode 0 (00000): Once per electrode. 1 (00001): Twice per electrode. 2 (00010): 3 times per electrode. 3 (00011): 4 times per electrode. 4 (00100): 5 times per electrode. 5 (00101): 6 times per electrode. 6 (00110): 7 times per electrode. 7 (00111): 8 times per electrode. 8 (01000): 9 times per electrode. 9 (01001): 10 times per electrode. 10 (01010): 11 times per electrode. 11 (01011): 12 times per electrode. 12 (01100): 13 times per electrode. 13 (01101): 14 times per electrode. 14 (01110): 15 times per electrode. 15 (01111): 16 times per electrode. 16 (10000): 17 times per electrode. 17 (10001): 18 times per electrode. 18 (10010): 19 times per electrode. 19 (10011): 20 times per electrode. 20 (10100): 21 times per electrode. 21 (10101): 22 times per electrode. 22 (10110): 23 times per electrode. 23 (10111): 24 times per electrode. 24 (11000): 25 times per electrode. 25 (11001): 26 times per electrode. 26 (11010): 27 times per electrode. 27 (11011): 28 times per electrode. 28 (11100): 29 times per electrode. 29 (11101): 30 times per electrode. 30 (11110): 31 times per electrode. 31 (11111): 32 times per electrode. |
LPSCNITV | TSI Low-Power Mode Scan Interval 0 (0000): 1 ms scan interval 1 (0001): 5 ms scan interval 2 (0010): 10 ms scan interval 3 (0011): 15 ms scan interval 4 (0100): 20 ms scan interval 5 (0101): 30 ms scan interval 6 (0110): 40 ms scan interval 7 (0111): 50 ms scan interval 8 (1000): 75 ms scan interval 9 (1001): 100 ms scan interval 10 (1010): 125 ms scan interval 11 (1011): 150 ms scan interval 12 (1100): 200 ms scan interval 13 (1101): 300 ms scan interval 14 (1110): 400 ms scan interval 15 (1111): 500 ms scan interval |
LPCLKS | Low-Power Mode Clock Source Selection 0 (0): LPOCLK is selected to determine the scan period in low-power mode. 1 (1): VLPOSCCLK is selected to determine the scan period in low-power mode. |